Promotion[[BUY 3 Get Extra 3% OFF!!],Free Shipping Worldwide Delivery

EXFO OTDR replaceable Swap-Out Connector APC or UPC With SC or FC - fusion splicer,splicing machine,otdr,fiber tool kits-TEKCN fusion splicer
UPC
EXFO OTDR replaceable Swap-Out Connector APC or UPC With SC or FC - fusion splicer,splicing machine,otdr,fiber tool kits-TEKCN fusion splicer
  • Load image into Gallery viewer, EXFO OTDR replaceable Swap-Out Connector APC or UPC With SC or FC - fusion splicer,splicing machine,otdr,fiber tool kits-TEKCN fusion splicer
  • Load image into Gallery viewer, UPC
  • Load image into Gallery viewer, EXFO OTDR replaceable Swap-Out Connector APC or UPC With SC or FC - fusion splicer,splicing machine,otdr,fiber tool kits-TEKCN fusion splicer

EXFO OTDR Swap-Out Connector – GP-3207 / GP-3208 SC or FC, APC or UPC for MAX-730D MAX-715D

Regular price
$196.88
Sale price
$196.88
Regular price
$365.00
Sold out
Unit price
per 
Shipping calculated at checkout.

EXFO OTDR Swap-Out Connector – GP-3207 / GP-3208 – SC or FC, APC or UPC – For EXFO MaxTester 700D OTDR series, including MAX-730D and MAX-715D, FTB-720D & 730D

The EXFO GP-3207 and GP-3208 are OEM Swap-Out Connectors for the EXFO MaxTester 700D OTDR series, including the MAX-730D and MAX-715D. Unlike traditional fixed OTDR optical ports, the MaxTester 700D’s Swap-Out connector system allows field technicians to replace the OTDR’s optical connector directly in the field — without sending the unit to a service centre — in seconds.

Advantage: the Swap-Out connector design enables iOLM support for both APC and UPC optical connectors. The internal connector is always APC, and always iOLM-compatible.

Note: UPC Swap-Out connectors will need to be replaced more often than APC Swap-Out connectors.

OX1 Click-Out connectors are NOT compatible with OTDRs. 700D OTDR Swap-Out connectors are NOT compatible with OX1.

Available in four configurations: SC/APC, SC/UPC, FC/APC, and FC/UPC.

Part Numbers & Connector Configurations

Part Number Connector Type Polish Type
GP-3207 SC APC (8° angled) or UPC
GP-3208 FC APC (8° angled) or UPC

Please select the correct connector type (SC or FC) and polish type (APC or UPC) to match your fiber network when ordering. If unsure, contact us before ordering.

Compatible EXFO OTDR Models

Series Compatible Models
EXFO 700D Series OTDRs MAX-715D, MAX-720D, MAX-730D, FTB-720D, FTB-730D

The Swap-Out Connector system is specific to the EXFO MaxTester 700D series. It is not compatible with older MAX-715B, MAX-720B, or FTB-series OTDRs, which use the EUI-series adapter system.

Key Features & Benefits

  • Field-Replaceable Without Service Centre: Replace the optical connector directly in the field in seconds — no tools, no service centre, no downtime.
  • EXFO OEM Part (GP-3207 / GP-3208): Genuine specified replacement connector — ensures correct optical alignment, insertion loss, and return loss performance.
  • Onboard Connector Health Diagnostic: The MaxTester 700D includes an onboard diagnostic tool that checks the connector’s condition and alerts the technician only when replacement is actually needed.
  • Four Connector Configurations: SC/APC, SC/UPC, FC/APC, and FC/UPC — covering the most common connector types in FTTH, PON, telecom OSP, and enterprise fiber networks.
  • Maintains Optimal OTDR Performance: Replacing with a new Swap-Out connector restores the OTDR’s specified dead zone and dynamic range performance.
  • Compact & Easy to Carry: Carry a spare Swap-Out connector in your OTDR case to replace a damaged connector immediately on site.

What Is an EXFO Swap-Out Connector and How Does It Work?

  1. Use the OTDR’s onboard connector health diagnostic to confirm replacement is needed
  2. Twist and remove the worn Swap-Out connector from the OTDR port
  3. Snap in the new GP-3207 (SC) or GP-3208 (FC) Swap-Out connector
  4. The OTDR is immediately ready for use — no calibration or service required

APC vs. UPC: Which Connector Polish Do You Need?

Polish Type End-Face Angle Typical Return Loss Common Applications
APC 8° angled >60dB FTTH / PON networks, CATV, long-haul telecom
UPC 0° flat >50dB Enterprise fiber, data centers, telecom OSP

Important: APC and UPC connectors are not interchangeable. Always match the Swap-Out connector polish type to your fiber network’s connector type.

Frequently Asked Questions

Q: What is the EXFO Swap-Out Connector?
A: The EXFO Swap-Out Connector (GP-3207 for SC, GP-3208 for FC) is a field-replaceable optical connector module for the EXFO MaxTester 700D OTDR series (MAX-715D, MAX-730D). It allows technicians to replace the OTDR’s optical connector in the field in seconds, without sending the unit to a service centre.

Q: What is the difference between GP-3207 and GP-3208?
A: The GP-3207 is the SC connector version (available in APC or UPC), and the GP-3208 is the FC connector version (available in APC or UPC).

Q: Which EXFO OTDR models are compatible with the Swap-Out Connector?
A: The Swap-Out Connector system is designed for the EXFO MaxTester 700D series: MAX-715D and MAX-730D. It is not compatible with older EXFO OTDR models such as the MAX-715B, MAX-720B, MAX-730, or FTB-series.

Q: Should I choose APC or UPC?
A: Choose APC if your fiber network uses green SC/APC or FC/APC connectors — common in FTTH, PON, and CATV networks. Choose UPC if your network uses blue SC/UPC or FC/UPC connectors. APC and UPC connectors are not interchangeable.

Q: Can I replace the Swap-Out Connector myself in the field?
A: Yes. Simply twist off the worn connector and snap in the new one. No calibration required.

Q: How do I know when to replace the Swap-Out Connector?
A: The EXFO MaxTester 700D includes an onboard connector health diagnostic tool that alerts you when replacement is needed.

Q: How many connectors come in one package?
A: Each package contains one (1) Swap-Out Connector. For bulk or B2B orders, contact us at sales@opticfibertool.com for volume pricing.

Package Contents

  • EXFO Swap-Out Connector (GP-3207 SC or GP-3208 FC, APC or UPC) ×1

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)